Many cold water storage tanks fitted in lofts before the 1980s were made of asbestos cement, a mix of cement and asbestos fibres. Removing an intact asbestos cement tank carefully, without breaking it, is usually non-licensed work, but it still needs trained operatives, a risk assessment, controls and correct hazardous waste disposal. If the tank has to be broken up to get it out of the loft, the work usually becomes notifiable. We test the tank, explain which category applies and plan removal across Liverpool and Merseyside.
How do I know if my loft water tank is asbestos?
Asbestos cement tanks are usually grey, heavy, square or rectangular, with thick walls and a slightly rough, fibrous or cement-like surface. Some have a separate lid, which may itself be asbestos cement or board. Plastic and galvanised steel tanks look very different, but an old tank that has been painted, stained or covered in insulation can be hard to judge. The only reliable answer is a sample analysed by a UKAS-accredited laboratory. Our asbestos sampling service can confirm it before plumbers or loft installers start.
Do not drill, cut, hammer or try to lift out a suspected asbestos cement tank. Do not jet-wash or scrub it. Leaving an intact tank alone is fine while you arrange testing.
Why are asbestos tanks so often found in Merseyside lofts?
Asbestos cement was a cheap, durable material for tanks, and these were widely fitted in houses built or modernised in the middle decades of the 20th century. That includes inter-war semis, post-war council-built estates and older terraces that had cold water storage added. Across Liverpool and the surrounding boroughs, from Norris Green to Huyton, many of these homes are now being re-plumbed with combination boilers that no longer need a loft tank. The old tank is often left behind, drained but still in place, until someone wants to board or convert the loft.
Is water tank removal licensed, notifiable or non-licensed?
HSE groups asbestos cement products, including water tanks, flues and roof sheets, in the lower-risk category, because the fibres are bound in cement. The category of work depends on how the tank comes out:
| Situation | Usual category |
|---|---|
| Tank intact and removed whole, without breaking | Non-licensed work |
| Tank needs to be significantly broken up to get it out, or is badly cracked | Usually notifiable non-licensed work (NNLW) |
| Tank badly damaged, with heavy debris | Licensed work may be needed |
Even non-licensed work carries legal duties under the Control of Asbestos Regulations 2012: a risk assessment, trained workers, suitable respiratory protective equipment and proper waste handling. NNLW also has to be notified to the enforcing authority before work begins, and the workers involved must have had a medical examination. Our non-licensed and NNLW work page explains the differences in more detail.
What if the tank will not fit through the loft hatch?
This is a common question. Some tanks were put in place before the ceiling or roof was finished, so they are larger than the hatch. That changes the plan. Options might include temporarily enlarging the hatch opening, which brings its own building considerations, or breaking the tank in a controlled way, which usually makes the job notifiable. Some owners decide to leave an intact, drained tank where it is, recorded, if it is not in the way. We look at the tank, the hatch and the space, then explain the choices and their categories before quoting. We do not decide on breaking a tank without telling you why.
What else is often found near an asbestos tank?
Lofts with asbestos tanks often hide other materials from the same era:
- Tank lids and platformsLids can be asbestos cement or insulating board, and some tanks sit on boarded platforms.
- Flue pipesGrey cement flues from older boilers or gas fires sometimes pass up through the loft. See asbestos flue removal.
- Insulating boardAIB was used for fire protection in some lofts and around hatches. AIB is licensable for most removal; our AIB removal page covers it.
- Old pipe insulationLagging on feed pipes is less common in lofts but needs to be ruled out.
Our guide to asbestos in the home shows where else these materials tend to appear.
How we plan water tank removal
- Call back. We ask about the tank, whether it is still in use, the size of the loft hatch, the age of the house and what you are planning, such as a loft conversion, new boiler or insulation.
- Testing. If needed, a sample is analysed by a UKAS-accredited laboratory and we explain the result in plain English.
- Isolation. If the tank is still connected, your plumber isolates and drains it before we start, so nobody is working with live water around the material.
- Written quote. We confirm whether the job is non-licensed or notifiable and what that means for timing.
- Removal. The tank is handled carefully, kept as intact as possible, wetted to suppress dust and wrapped in heavy-duty polythene before it is lowered from the loft.
- Disposal. Waste goes to a site permitted to accept asbestos with a hazardous waste consignment note, which we give you a copy of.
What affects the cost?
Cost depends on the size and weight of the tank, whether it can come out whole, loft access and headroom, whether the hatch needs enlarging, whether the job is notifiable, testing, and waste volume. Our cost guide sets out the factors. Removing a tank often goes hand in hand with other loft work, and it can make sense to deal with any flue or board at the same visit. You can find our full range of services on our local asbestos removal service page.
Can I leave an asbestos water tank in the loft?
If the tank is intact, will not be disturbed and nobody is working near it, leaving it in place is often reasonable. HSE guidance is that undamaged asbestos which will not be disturbed is often safest managed where it is. Problems start when the loft is boarded, converted, rewired or insulated around it, or when the tank cracks. Before any of that work, have it tested and decide whether to remove it. As a team handling asbestos removal across Merseyside, we will give you an honest view either way.
Old cement tank in your loft?
Call 07777 659786 or send your details. Tell us the size of the tank and hatch, whether it is still in use and what you are planning, and we will call you back to talk through testing and removal.
Frequently asked questions
Is it illegal to have an asbestos water tank in the loft?
No. There is no general requirement for homeowners to remove asbestos cement tanks. Asbestos in good condition that will not be disturbed is often safest left alone. What matters is that anyone working in the loft knows it is there, so it is not drilled, cut or broken. If you are planning loft work, have it tested and assessed first.
Can my plumber take out the old asbestos tank?
A plumber can isolate and drain it, but removing an asbestos cement tank is asbestos work under the Control of Asbestos Regulations 2012. It needs a risk assessment, trained workers, controls and correct hazardous waste disposal, and if it must be broken up it usually becomes notifiable. Most plumbers prefer to leave that part to an asbestos specialist.
Can an asbestos water tank be sealed instead of removed?
Sealing an asbestos cement tank in good condition is possible and is classed by HSE as non-licensed work. It suits a drained tank that will stay in a loft nobody uses. It is not removal, so the tank still needs recording and checking. Our asbestos encapsulation page explains when sealing makes sense.
How long does removing an asbestos water tank take?
An intact tank that comes out through the hatch is often a short job, usually completed within a day. If the tank needs breaking up and the work is notifiable, there is notification to complete first, and the job itself takes longer. We explain the likely timing once we know the tank size, hatch size and condition.
Is the lid of an old water tank asbestos too?
It can be. Lids on older cold water tanks were sometimes asbestos cement and sometimes insulating board, which is a higher-risk material. Others were wood or plastic. Because AIB is usually licensable to remove, it is worth having the lid sampled separately rather than assuming it matches the tank.